Reliable Energy Storage — Download Free Catalog Download Now
Illustrated winter site for a two-story solar and battery pilot building in Mongolia
MONGOLIAPROJECT DESIGN

PROJECT DESIGN · MONGOLIA

Solar Battery Storage in Mongolia: A Winter Pilot

01

Start with one building

The first building in this proposed Mongolian pilot has about 150 m² of floor area across two stories. The project brief allows for 14 panels on the roof. The proposed system pairs 9.1 kWp of rooftop solar with 28.67 kWh of nominal battery storage and a separate 10 kW single-phase hybrid inverter.

The project team would start here and see how the equipment performs through winter before deciding whether to use the same package at 19 similar buildings.

02

Fit 14 panels to the roof

The design calls for 14 modules rated at 650 Wp each. On the roof plan, mark where winter shade falls and where someone could reach the panels for inspection or snow clearing. Set aside that space before laying out the rows. The installer can check the mounting surface and roof loading on the same visit.

Then follow the proposed cable route down to the inverter. The installer can price the mounting and cable work once the roof plan and equipment location are clear.

Illustrated roof layout with 14 solar modules and a maintenance access strip
03

Choose where the batteries will sit

Start by checking the room where the batteries could go. If it stays within the battery’s operating limits, the indoor model is an option. If space inside is tight, ask the installer to assess a sheltered location for the IP65 model. In both layouts, allow access to the two battery units and the separate inverter, and measure how cold it gets where the batteries would actually sit.

Battery options for the pilot building
Battery optionNominal energy per buildingProposed placementWhat to confirm before ordering
A · IP20 indoor model28.67 kWh from two unitsDry indoor equipment room with temperature controlThe room stays within the supplied model's charging and discharging limits
B · IP65 enclosure model28.67 kWh from two unitsSheltered location assessed against the supplied model's installation limitsMinimum charging temperature, whether the heating option is included, and how it is powered
Option A · Indoor equipment roomOption B · Sheltered equipment area
Illustrated comparison of indoor and sheltered battery placement options at the same pilot building

Both routes use two matching 51.2 V, 280 Ah LFP units. The enclosure rating describes protection against dust and water. Ask the supplier for the separate charging and discharging limits for the battery configuration you would receive.

04

Decide what to power during winter outages

Walk the distribution panel with the installer and list the circuits that need to stay on. Lighting, controls and communications are useful circuits to review first.

Put space heating on a separate line in the load list. Record its running demand and how long it would need to operate during a typical outage. Include that figure in the sizing check before adding heating to the backup circuits.

The 10 kW figure is the inverter's nameplate rating. Ask the installer to check the available backup output, the battery discharge limit and what happens when loads start together. Agree on how the selected circuits transfer to backup and how the batteries recharge afterwards. If the building has a utility connection, confirm the intended connection and export arrangements with the installer before finalizing the design.

Functional diagram linking the 9.1 kWp roof array, 10 kW inverter, 28.67 kWh battery bank and priority circuits
05

Price the first equipment package

The equipment below has a planning budget of US$5,000–6,000 per building. The battery option and any heating accessory affect the final quote.

Equipment supply for one building
EquipmentQuantityProposed specification
Solar modules14650 Wp each, 9.1 kWp total
LFP battery units2Two matching units from either option, 28.67 kWh nominal total
Hybrid inverter110 kW single-phase unit

Budget separately for roof mounting, site wiring and protection, freight, import charges and local installation. Confirm any battery heating accessory and delivery terms when requesting a quote.

06

Use the pilot to decide what to repeat

Keep a winter log for the pilot. Note the lowest temperature at the batteries, how much power the selected circuits draw and whether they stay on when supply transfers. Record how much charge the array puts back into the battery.

Keep the log with the roof and equipment plans. Then compare the next buildings for differences in shading, available equipment space, minimum temperatures and load.

See KUNETIC's residential energy storage solutions for system options or the Saudi home solar and battery case for another equipment layout. Select Plan Your Winter Solar and Battery System to share your roof dimensions, minimum equipment-area temperature, load records and supply arrangement.

07

Questions about the pilot

How long will 28.67 kWh of storage last?

Estimate runtime from the measured demand of the selected circuits and the battery energy available at the start of the outage. Account for the reserve setting, conversion losses and temperature limits for the supplied battery.

Can the IP65 option go outdoors in winter?

Check the proposed location against the supplied model's installation instructions. Ask for its minimum charging temperature and confirm whether the ordered units include heating.

Can the 10 kW inverter run the heating equipment?

Give the installer the heating equipment's nameplate, typical running demand and expected operating hours. They can compare that load and any starting demand with the inverter's backup output and the battery's available energy.

What equipment does the budget cover?

It covers 14 solar modules, two matching battery units and a single-phase hybrid inverter. Roof mounting, site electrical work, freight, import charges and local installation are priced separately.

PROJECT ENQUIRY

Plan Your
Winter Solar and Battery System

Share the building details, winter temperatures and loads you want to support.

Illustrated winter site for a two-story solar and battery pilot building in Mongolia
Visit our contact page

Plan Your Winter Solar and Battery System

Share the building details, winter temperatures and loads you want to support.

Minimum 10 characters.

Drag & Drop a Project File Here

PDF, JPG, PNG, WEBP, DOCX, XLSX or ZIP · Max 8 MB