LiFePO4 Voltage Chart for 12V, 24V and 48V Batteries
Use this LiFePO4 battery voltage chart as a rough guide to charge level. First check your pack’s cell count and whether it is resting, charging or powering a load. Voltage alone cannot pinpoint how much charge remains.
These reference points come from Renogy’s LiFePO4 voltage guide. Each pack value is its cell voltage multiplied by the series cell count. For a 12V LiFePO4 voltage chart, read the 4S column. The 48V LiFePO4 voltage chart here uses 16S; check your pack’s cell count first.
Reference SOC | One cell | 12V class: 4S | 24V class: 8S | 48V class: 16S |
Near full, at rest | 3.40V | 13.60V | 27.20V | 54.40V |
About 70% | 3.30V | 13.20V | 26.40V | 52.80V |
About 50% | 3.26V | 13.04V | 26.08V | 52.16V |
About 20% | 3.20V | 12.80V | 25.60V | 51.20V |
About 10% | 3.00V | 12.00V | 24.00V | 48.00V |
Your battery may differ from these estimates. Renogy does not document all test conditions for these SOC points. You cannot use this table to calibrate your battery’s SOC.
For comparison, follow your maker’s rest instructions and record no-load voltage. Readings under load or during charging may differ. These rows are not charger or shutdown settings.
Nominal Voltage vs. the Reading on Your Meter
Nominal voltage identifies the battery’s voltage class. The meter reading changes as you charge or use it.
A LiFePO4 cell is commonly rated at 3.2V nominal. Series cell voltages add together:
Battery class | Series cells | Nominal pack voltage |
12V | 4S | 12.8V |
24V | 8S | 25.6V |
48V | 15S | 48.0V |
48V class / 51.2V | 16S | 51.2V |
48V vs. 51.2V: Check the Cell Count
A “48V” system may use a 15S or 16S pack. Their voltage ranges differ because one contains an extra series cell. PowMr’s pack-voltage guide explains this distinction.
The first chart uses 16S for its 48V-class column. For a 15S reference, multiply the cell voltage by 15 instead. Before connecting equipment, check that the battery’s operating range fits the inverter’s compatible range. The “48V” label alone is insufficient.
Can Battery Voltage Tell You the State of Charge?
LiFePO4 voltage stays fairly flat through much of its usable charge range. A small voltage difference can correspond to a substantial change in remaining charge. Victron’s lithium discharge-curve comparison illustrates this flatter behavior.

Illustrative LiFePO4 curve showing the broad voltage plateau. This is a shape diagram, not measured battery data or an SOC calibration.
The table associates 13.20V with about 70% on a 4S pack. A reading alone cannot establish 70% SOC for your battery, especially while solar charging or a load is active.
For day-to-day monitoring, use a correctly configured battery monitor or the battery’s supported SOC display. Current-based monitors track charge flowing in and out over time; Victron’s BMV explanation describes this method. Correct capacity settings and synchronization still matter.
Read voltage alongside current, SOC and alarms. You also need individual cell readings to check cell balance; our BMS guide explains cell monitoring and protection.
Why Your Voltage Reading May Differ
Resting Voltage
Resting voltage is measured with no charging or load current, after the battery has settled. After charging, the voltage can fall as the battery settles. That fall does not mean it has lost the same proportion of stored charge.
For instance, LiTime’s guide describes a fully charged cell settling around 3.35V at rest. Charging endpoints and generic charts can show different values. For comparison, follow the conditions documented for your battery.
Voltage While Charging
Charging raises terminal voltage. A 4S pack may approach 14.6V when its specified charging limit is 3.65V per cell. The voltage will settle after charging stops, so use this figure only as a charging reference.
Note whether the charger is active when you take the reading.
Voltage Under Load
An inverter or other load can lower terminal voltage. The drop depends on current and electrical resistance. Voltage can recover when the load stops. This behavior is discussed in Victron’s cutoff explanation.
Compare readings under similar conditions. Temperature can also affect battery behavior; note it when investigating a change.
Charging Voltage and Low-Voltage Limits
Use your battery model’s manual to set charging voltage and low-voltage shutdown. Follow its instructions for absorption time and float behavior too. A generic SOC table does not supply those settings.
For example, Victron’s Lithium Battery Smart specifications recommend charging its 12.8V batteries at 14.2V. For its 25.6V batteries, the recommended charging voltage is 28.4V. They list end-of-discharge values of 11.2V and 22.4V respectively. Those are product-specific figures.
A charger’s target, an inverter’s shutdown setting and a BMS protection threshold perform different jobs. Check each in its equipment documentation. One “empty battery” voltage cannot serve all three purposes.
For broader battery selection, see our lithium-ion solar battery guide.
How to Check and Interpret Battery Voltage
For an accessible low-voltage battery:
- Confirm LiFePO4 chemistry, nominal voltage and series cell count.
- Note whether charging or a load is active. For a resting comparison, follow the maker’s isolation and rest instructions.
- Use a suitably rated meter in DC voltage mode. Put the black lead in COM and the red lead in the voltage input, not the current input.
- Measure across the designated terminals, red to positive and black to negative, following the meter and battery manuals.
- Compare the reading with the correct chart, then check SOC and any BMS alarms before changing settings.
Fluke’s DC voltage measurement guide explains the meter setup.

Illustration of a low-voltage battery measurement. Meter settings and the battery’s charging or load state affect interpretation.
Where Industrial Battery Cabinets Differ
The low-voltage charts above do not apply directly to industrial high-voltage cabinets.
KUNETIC’s eBlock 120kWh Outdoor DC Battery Cabinet uses a 1P120S LFP configuration and operates at 336–432Vdc. It requires an external PCS.

KUNETIC eBlock 120kWh Outdoor DC Battery Cabinet: 336–432Vdc, with an external PCS required.
Use the cabinet’s supported monitoring system and qualified service procedures for inspection. For a commercial storage project, review the eBlock data sheet. Share your PCS model with KUNETIC to check whether the voltage ranges match.
Frequently Asked Questions
Does a Higher Ah Rating Mean Higher Battery Voltage?
No. Ah describes charge capacity; voltage describes electrical potential difference. Batteries can share a nominal voltage while having different Ah ratings. Our battery Ah guide explains the relationship between capacity, voltage and stored energy.
Can I Use a Lead-Acid Voltage Chart for LiFePO4?
No. The chemistries have different voltage curves. Use a LiFePO4 reference that matches your pack’s series cell count and measurement conditions.
Why Do Different LiFePO4 Voltage Charts Disagree?
They may use different cells, temperatures, loads, rest periods or rounding. Some also mix charging endpoints with resting values. Check the battery maker’s documentation. When you need a dependable remaining-charge estimate, use a correctly configured current-based monitor.