Reliable Energy Storage — Download Free Catalog Download Now
257 kWh KUNETIC outdoor DC battery cabinet, front view on white

Commercial & Industrial Storage

257kWh Outdoor DC Battery Storage Cabinet for Commercial Solar and Peak Shaving

Store surplus rooftop solar for a later shift, or use stored power when your facility draws the most from the grid. The KUNETIC 257kWh outdoor battery storage cabinet houses 16 LFP battery packs in an IP54 enclosure. It also includes battery management, air conditioning and fire protection. Pair the cabinet with a compatible external power conversion system (PCS). You can size the battery around how much energy you want to store and choose the PCS around the power your site needs.

257 kWh Rated Battery Energy
819.2 V Nominal DC Voltage
314 Ah LFP Cell Capacity
IP54 Cabinet Protection

Features

Outdoor Storage Built Around Your PCS

  • Battery capacity

    257 kWh in one outdoor cabinet

    Sixteen packs built with 314 Ah LFP cells provide 257 kWh of rated DC energy. Put the storage in an outdoor equipment area and preserve floor space inside your facility.

  • Outdoor enclosure

    Air conditioning in an IP54 enclosure

    Air conditioning manages battery temperature inside the IP54 enclosure. Set aside one space for the battery and its cooling equipment when planning the site.

  • Monitoring & protection

    Battery monitoring and fire protection

    The battery management system (BMS) provides electrical protection at pack, cluster and cabinet levels. Temperature and smoke detection and aerosol fire suppression are built into the configuration.

  • Parallel expansion

    Start with one cabinet and expand

    Start with one cabinet and add storage as demand grows. With a compatible PCS and coordinated controls, the battery platform supports up to ten cabinets in parallel.

Cabinet ventilation grille, three status lights and service door

Match the Cabinet to Your PCS

If your facility already has rooftop solar, you can keep its PV inverter in a suitable AC-coupled retrofit. A separate bidirectional PCS connects the battery to the site’s AC system. The site controls use meter readings to tell the PCS when to charge the battery with surplus solar and when to supply power to the building.

A typical AC-coupled retrofit with rooftop PV and its inverter, a separate bidirectional PCS and DC battery cabinet, site loads, meter and grid

Check these three points before selecting the PCS.

  1. DC voltage. Start with the cabinet’s 716.8–934.4 V operating range. Compare the PCS battery input limits and confirm the voltage window the two devices can use together.
  2. Current and power. The battery’s rated charge and discharge current is 157 A. At a given current, DC power falls as battery voltage drops. Check the target AC output against the available DC voltage and current over the planned operating window.
  3. Communication. The cabinet has CAN, RS485 and RS232 interfaces. Share the exact PCS model so we can check the battery protocol, command support and operating limits.

For a site with solar already in place, see our guide to adding battery storage to an existing commercial PV system. If you prefer to source power conversion and storage as one unit, compare the 125kW / 261kWh integrated commercial BESS.

Plan Space for One Cabinet or Several

The cabinet measures 1,090 × 1,300 × 2,350 mm (W × D × H) and weighs approximately 2,620 kg. The cabinet itself occupies about 1.42 m². Allow separate space for the PCS and leave room for delivery, service access and ventilation.

Two matching outdoor battery cabinets arranged side by side

Cabinet Access From Above

Side by side

Both service doors face the same aisle.

Back to back

The rear panels face each other, with service access on opposite sides.

Cabinets can be arranged side by side or back to back if the site layout allows. If you expect to expand later, plan the equipment area, PCS capacity, protection and controls for the proposed cabinet count early. More cabinets add energy capacity. Your installed PCS and the battery system together determine available AC power.

If you need less storage or have a different PCS voltage range, compare the 160–241 kWh outdoor battery cabinet series.

Applications

Outdoor battery equipment beside the solar roof of a food processing facility

Put rooftop solar to work on a later shift

If your food processing plant has solar left over at midday, a 257kWh battery cabinet with a matched PCS can store it for packaging, washdown or other operations later in the shift. Compare the site’s solar generation and load by time of day to see when energy is available to store and when it would be useful.

Outdoor battery cabinet in the equipment area of a refrigerated logistics facility

Shave demand peaks at a cold-chain distribution centre

When refrigeration, defrost cycles and loading activity overlap, site demand can rise. With a matched PCS and site controls, the battery can discharge during these windows to reduce the power drawn from the grid.

To trim 80 kW for two hours, the system needs to deliver 160 kWh on the AC side. Compare that requirement with the energy the battery can deliver after allowing for its operating window, reserve, conversion losses and auxiliary loads. Then check that the battery and PCS can sustain the required discharge power for the full period.

Technical Specifications

KUNETIC 257kWh Outdoor DC Battery Cabinet Technical Specifications

Engineering data from the product sheet.

MODEL
257kWh Outdoor DC Battery Cabinet
Battery and DC electrical
Cell chemistry and rating LFP, 3.2 V / 314 Ah
Battery pack configuration 1P16S, 16.07 kWh per pack
Cabinet configuration 16 packs, 1P256S
Rated battery energy 257 kWh
Nominal DC voltage 819.2 V
Operating DC voltage 716.8–934.4 V
Rated charge / discharge current 157 A / 157 A
Maximum charge / discharge current 200 A / 200 A
Cabinet and protection
Cooling Air conditioning
Cabinet ingress protection IP54
Fire detection and suppression Temperature and smoke detection, aerosol fire suppression
Cabinet dimensions (W × D × H) 1,090 × 1,300 × 2,350 mm
Cabinet weight Approx. 2,620 kg
Integration and environment
Communication interfaces CAN, RS485, RS232
Parallel expansion Up to 10 battery cabinets with a compatible PCS and controls
Power conversion Matched external PCS, selected separately
Charging temperature 0 to 45 °C
Discharging temperature −20 to 45 °C
Storage temperature −20 to 45 °C
Relative humidity 0–95%, non-condensing
Site altitude Up to 3,000 m, with derating above 2,000 m
Technical data cover Technical Data

Downloads

257kWh Outdoor DC Battery Storage Cabinet Datasheet

Request the technical data for checking PCS compatibility and planning the equipment area. If you have selected a PCS, include the exact model in your request.

FAQ

The cabinet includes the LFP battery packs, BMS, cooling and cabinet protection. A compatible external PCS is selected separately to connect the DC battery to the site’s AC electrical system.

An existing solar inverter can remain on the AC side in a suitable retrofit. For direct battery connection to your existing PCS or hybrid inverter, check its DC voltage and current limits and the exact BMS protocol. Share the model and site voltage so we can review both options.

The battery stores 257 kWh of rated DC energy. The energy available to your loads depends on the battery’s starting charge, the operating window and reserve, auxiliary consumption and PCS conversion losses. For a useful estimate, share the target discharge power and how long you need it.

Yes. The platform supports up to ten battery cabinets in parallel with compatible power conversion and controls. If you expect to add cabinets later, include the future cabinet count in the initial PCS, electrical protection and site layout review.

The cabinet can store energy for backup when paired with a PCS and switching equipment that serve selected loads during a grid outage. Share the critical circuits, starting and running loads, and how long they need to operate.

Find the right storage configuration for your site

Tell us where the system will go and what you want it to do. If you have a load profile, send it along with the site voltage, existing solar capacity and any PCS model you’ve already chosen. We can compare the 257kWh cabinet with other capacities and help size the equipment for your site.

OEM / ODM

Configure the cabinet for your project or product range

Ask about branding, labels and documentation for your market. If you supply commercial solar or storage projects, share your preferred PCS, capacity target and equipment layout so we can review the cabinet and system options together.

Discuss Your Project